CHECK POWER WINDOW MAIN SWITCH.

Check the continuity when the power window switch is operated to the UNLOCK direction.

Connector & terminal

(D102) No. 1 — (D102) No. 3:

QUESTION

Did the indicator change from “No continuity” (1 MΩ or more) to “Continuity exists” (less than 10 Ω)?

Yes No

Replace the power window main switch.