CHECK SUCTION CONTROL VALVE.

Measure the resistance between suction control valve terminals.

NOTE:

Measure the resistance when suction control valve temperature is 20°C (68°F).

Terminals

No. 1 — No. 2:

QUESTION

Is the resistance 1.8 — 2.4 Ω?

Yes No

The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

NOTE:

In this case, temporary poor contact of connector may be the cause.

Replace the suction control valve.