| CHECK INPUT VOLTAGE OF STARTER RELAY. |
|
1) Remove the starter relay. 2) Connect the connector to ignition switch. 3) Turn the ignition switch to START. 4) Measure the voltage between starter relay connector and chassis ground. Connector & terminal LHD model (B225) No. 9 (+) — Chassis ground (−): RHD model (B225) No. 23 (+) — Chassis ground (−): |