1) Disconnect the connectors from the ECM.
2) Measure the resistance between ECM and chassis ground.
Connector & terminal
(B136) No. 20 — Chassis ground:
Is the resistance 1 MΩ or more?
Repair the short circuit to ground in harness between ECM and starter relay connector.