CHECK PURGE CONTROL SOLENOID VALVE 2.

1) Turn the ignition switch to OFF.

2) Measure the resistance between purge control solenoid valve 2 terminals.

Terminals

No. 1 — No. 2:

QUESTION

Is the resistance less than 1 Ω?

Yes No

Replace the purge control solenoid valve 2.

Repair the poor contact of the ECM connector.