| CHECK HARNESS BETWEEN ECM AND SECONDARY AIR PUMP RELAY. |
|
Measure the resistance between ECM and chassis ground. Connector & terminal (B136) No. 8 — Chassis ground: |
| QUESTION | |
|
Is the resistance 1 MΩ or more? | |
| Yes | No |
|
Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the fault condition, and reperform the check. NOTE: In this case, there may be a temporary connector contact failure. |
Repair ground short of the harness between the ECM and secondary air pump relay. |