CHECK HARNESS BETWEEN ECM AND SECONDARY AIR PUMP RELAY.

Measure the resistance between ECM and chassis ground.

Connector & terminal

(B136) No. 8 — Chassis ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the fault condition, and reperform the check.

NOTE:

In this case, there may be a temporary connector contact failure.

Repair ground short of the harness between the ECM and secondary air pump relay.