CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY.

Measure the resistance between ECM and chassis ground.

Connector & terminal

(B135) No. 15 — Chassis ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the fault condition, and reperform the check.

NOTE:

In this case, there may be a temporary connector contact failure.

Repair ground short circuit of the harness between ECM and secondary air combination valve relay.