CHECK HARNESS BETWEEN ECM AND PURGE CONTROL SOLENOID VALVE.

1) Turn the ignition switch to OFF.

2) Disconnect the connectors from ECM and purge control solenoid valve.

3) Measure the resistance between the purge control solenoid valve connector and engine ground.

Connector & terminal

(E4) No. 2 — Engine ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Repair the ground short circuit of harness between ECM and purge control solenoid valve connector.