CHECK HARNESS BETWEEN ECM AND WASTEGATE CONTROL SOLENOID VALVE.

1) Turn the ignition switch to OFF.

2) Disconnect the connectors from ECM and wastegate control solenoid valve.

3) Turn the ignition switch to ON.

4) Measure the voltage between ECM and chassis ground.

Connector & terminal

(B137) No. 27 (+) — Chassis ground (−):

QUESTION

Is the voltage 10 V or more?

Yes No

Repair short circuit to power in the harness between ECM and wastegate control solenoid valve connector.