CHECK HARNESS.

Using the tester, measure the voltage between keyless entry control module and chassis ground.

Connector & terminal

(R80) No. 4 (+) — Chassis ground (−):

QUESTION

Is the voltage battery voltage?

Yes No

Check the power supply circuit for keyless entry control module.