CHECK HARNESS BETWEEN STARTER RELAY AND INHIBITOR SWITCH.

1) Disconnect the connector from inhibitor switch.

2) Measure the resistance of harness between starter relay connector and inhibitor relay connector.

Connector & terminal

LHD model

(B225) No. 10 — (T7) No. 6:

RHD model

(B225) No. 25 — (T7) No. 6:

QUESTION

Is the resistance less than 1 Ω?

Yes No

Repair the harness and connector.

NOTE:

In this case, repair the following item:

Open circuit in harness between starter relay connector and inhibitor switch connector

Poor contact of coupling connector