CHECK HARNESS CONNECTOR BETWEEN COMBINATION METER AND AMBIENT SENSOR.

Measure the resistance of harness between combination meter and ambient sensor.

Connector & terminal

(F78) No. 2 — (i10) No. 23:

QUESTION

Is the resistance less than 1 Ω?

Yes No

Replace the combination meter.

Repair the open circuit in the harness between the combination meter and ambient sensor.