LIGHTING SYSTEM > Turn Signal Light and Hazard Light System

INSPECTION

1. TURN SIGNAL SWITCH

Measure the resistance between turn signal switch terminals.

2. HAZARD SWITCH

Measure the resistance between hazard switch terminals.

Switch position

Terminal No.

Standard

OFF

2 and 3

1 MΩ or more

ON

Less than 1 Ω

Replace the hazard switch if faulty.

3. TURN SIGNAL AND HAZARD MODULE

Connect the battery and turn signal light bulb to the module. The module is properly functioning if it blinks when power is supplied to the circuit.

Replace the turn signal & hazard module if faulty.