LIGHTING SYSTEM > Room Light
1. Visually check the bulb for blow out.
3. If NG, replace the bulb with a new part.
1. Measure the resistance between room light switch terminals.
|
(A) |
Model without sunroof |
|
(B) |
Model with sunroof |
|
Switch position |
Terminal No. |
Standard |
|
OFF |
— |
1 MΩ or more |
|
ON |
1 and 3 |
1.5±0.5 Ω |
|
Door |
2 and 3: Model without sunroof 1 and 2: Model with sunroof |
1.5±0.5 Ω |
2. Check the room light illumination condition.
• Model without sunroof
Connect terminal No. 3 to the battery positive terminal and terminal No. 1 and No. 2 to the battery ground terminal.
• Model with sunroof
Connect terminal No. 1 to the battery positive terminal and terminal No. 2 and No. 3 to the battery ground terminal.
|
Switch position |
Light status |
|
OFF |
Light OFF |
|
ON |
Light ON |
|
Door |
Light ON |
3. Replace the room light if faulty.