FUEL INJECTION (FUEL SYSTEMS)(H4DOTC DIESEL) > Fuel Level Sensor
1. Check the fuel tube for disconnection or clogging.
2. Check the float for smooth operation.
3. Measure the resistance between fuel level sensor connector terminals.
Standard:
|
Float position |
Resistance |
|
FULL |
1 — 3 Ω |
|
EMPTY |
31 — 33 Ω |
|
(A) |
FULL |
(B) |
EMPTY |
(C) |
111.3 mm (4.3819 in) |