DTC B1101 BATT P/SUPPLY MALFUNCTION CONT
DTC DETECTING CONDITION:
• Battery power supply control circuit is open or shorted.
• Voltage malfunction caused by poor contact
TROUBLE SYMPTOM:
Each function stops operation.
NOTE:
• When B1102 BATT p/supply (backup) malfunction is output at the same time, all the function of body integrated unit may not operate.
• B1101 may input when the battery run-out occurs.
WIRING DIAGRAM:
| STEP | CHECK | YES | NO |
|
Is B1101 current malfunction? |
|||
|
Is B1101 current malfunction? |
|||
|
Is fuse normal? |
Replace the defective fuse. |
||
|
Is the voltage 8.5 — 16.5 V? |
Repair or replace the open or shorted circuit between body integrated unit and fuse. |
||
|
Is there poor contact of connector? |
Repair or replace the poor contact of connector. |
A temporary change of voltage occurred. |