ENGINE (DIAGNOSTICS)(H4SO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)

DTC P0076 INTAKE VALVE CONTROL SOLENOID CIRCUIT LOW (BANK 1)

DTC DETECTING CONDITION:

Immediately at fault recognition

TROUBLE SYMPTOM:

Improper idling

CAUTION:

After repairing or replacing the defective part, perform the Clear Memory Mode and Inspection Mode .

WIRING DIAGRAM:

STEPCHECKYESNO

1.CHECK HARNESS BETWEEN ECM AND OIL SWITCHING SOLENOID VALVE RH.

1) Turn the ignition switch to OFF.

2) Disconnect the connectors from the ECM and oil switching solenoid valve RH.

3) Measure the resistance of harness between ECM and oil switching solenoid valve RH connector.

Connector & terminal

(B137) No. 25 — (E69) No. 1:

(B137) No. 24 — (E69) No. 2:

Is the resistance less than 1 Ω?

Repair the harness and connector.

NOTE:

In this case, repair the following item:

Open circuit in harness between ECM and oil switching solenoid valve RH connector

Poor contact of coupling connector

2.CHECK HARNESS BETWEEN ECM AND OIL SWITCHING SOLENOID VALVE RH.

Measure the resistance between ECM and chassis ground.

Connector & terminal

(B137) No. 25 — Chassis ground:

(B137) No. 24 — Chassis ground:

Is the resistance 1 MΩ or more?

Repair the short circuit to ground in harness between ECM and oil switching solenoid valve RH connector.

3.CHECK OIL SWITCHING SOLENOID VALVE RH.

Measure the resistance between oil switching solenoid valve RH terminals.

Terminals

No. 1 — No. 2:

Is the resistance between 6 — 12 Ω?

Repair the poor contact of ECM and oil switching solenoid valve RH connector.

Replace the oil switching solenoid valve RH.