CRUISE CONTROL SYSTEM (DIAGNOSTICS) > Engine Control Module (ECM) I/O Signal

ELECTRICAL SPECIFICATION

1. GASOLINE ENGINE MODEL

Turbo model

Content

Terminal No.

Measurement condition and I/O signal

(Idling with ignition ON: except for cruise set light)

Main power supply

VB (CONTROL 1)

VB (CONTROL 2)

A7, B2

Battery voltage is detected when the main power is turned ON.

“0 V” is detected when the main power is turned OFF.

Command switch

B24

“0 V” is detected when the command switch is in CANCEL position.

“Approx. 1 V” is detected when the command switch is in SET/COAST position.

“Approx. 3 V” is detected when the command switch is in RESUME/ACCEL position.

“Approx. 4 V” is detected when the command switch is released.

Brake switch 1

(Brake switch)

B20

Battery voltage is detected when the brake pedal is released.

“0 V” is detected when brake pedal is depressed.

Brake switch 2

(Stop light switch)

B28

Battery voltage is detected when brake pedal is depressed.

“0 V” is detected when the brake pedal is released.

Main switch

B12

“0 V” is detected while the main switch is pressed or turned on.

Approx. “5 V” is detected when the main switch is OFF.

Ground

GND (CONTROL 1)

GND (CONTROL 2)

A5

C15

Ignition switch

B19

Battery voltage is detected when the ignition switch is turned ON.

“0 V” is detected when the ignition switch is turned OFF.

Clutch switch

(MT model)

C25

“0 V” is detected when clutch pedal is depressed.

Battery voltage is detected when the clutch pedal is released.

Neutral position switch (MT model)

C31

Battery voltage is detected when the shift lever is in any position except for neutral.

“Approx. 0 V” is detected when the shift lever is in neutral position.

Neutral signal (AT model)

C31

Battery voltage is detected when the shift lever is in any position except for “P” or “N”.

“0 V” is detected when the shift lever is in “P” or “N” position.

2.0 L non-turbo model

Content

Terminal No.

Measurement condition and I/O signal

(Idling with ignition ON: except for cruise set light)

Main power supply

VB (CONTROL 1)

VB (CONTROL 2)

C3, C4

Battery voltage is detected when the main power is turned ON.

“0 V” is detected when the main power is turned OFF.

Command switch

C23

“0 V” is detected when the command switch is in CANCEL position.

“Approx. 1 V” is detected when the command switch is in SET/COAST position.

“Approx. 3 V” is detected when the command switch is in RESUME/ACCEL position.

“Approx. 4 V” is detected when the command switch is released.

Brake switch 1

(Brake switch)

C12

Battery voltage is detected when the brake pedal is released.

“0 V” is detected when brake pedal is depressed.

Brake switch 2

(Stop light switch)

C13

Battery voltage is detected when brake pedal is depressed.

“0 V” is detected when the brake pedal is released.

Main switch

C14

“0 V” is detected while the main switch is pressed or turned on.

Approx. “5 V” is detected when the main switch is OFF.

Ground

GND (CONTROL 1)

GND (CONTROL 2)

D6

D7

Ignition switch

B10

Battery voltage is detected when the ignition switch is turned ON.

“0 V” is detected when the ignition switch is turned OFF.

Clutch switch

(MT model)

C25

“0 V” is detected when clutch pedal is depressed.

Battery voltage is detected when the clutch pedal is released.

Neutral position switch (MT model)

C31

Battery voltage is detected when the shift lever is in any position except for neutral.

“Approx. 0 V” is detected when the shift lever is in neutral position.

Neutral signal (AT model)

C31

Battery voltage is detected when the shift lever is in any position except for “P” or “N”.

“0 V” is detected when the shift lever is in “P” or “N” position.

2.5 L non-turbo model

Content

Terminal No.

Measurement condition and I/O signal

(Idling with ignition ON: except for cruise set light)

Main power supply

VB (CONTROL 1)

VB (CONTROL 2)

A7, B2

Battery voltage is detected when the main power is turned ON.

“0 V” is detected when the main power is turned OFF.

Command switch

B24

“0 V” is detected when the command switch is in CANCEL position.

“Approx. 1 V” is detected when the command switch is in SET/COAST position.

“Approx. 3 V” is detected when the command switch is in RESUME/ACCEL position.

“Approx. 4 V” is detected when the command switch is released.

Brake switch 1

(Brake switch)

B20

Battery voltage is detected when the brake pedal is released.

“0 V” is detected when brake pedal is depressed.

Brake switch 2

(Stop light switch)

B28

Battery voltage is detected when brake pedal is depressed.

“0 V” is detected when the brake pedal is released.

Main switch

B12

“0 V” is detected while the main switch is pressed or turned on.

Approx. “5 V” is detected when the main switch is OFF.

Ground

GND (CONTROL 1)

GND (CONTROL 2)

A5

C15 (MT model only)

Ignition switch

B19

Battery voltage is detected when the ignition switch is turned ON.

“0 V” is detected when the ignition switch is turned OFF.

Clutch switch

(MT model)

C25

“0 V” is detected when clutch pedal is depressed.

Battery voltage is detected when the clutch pedal is released.

Neutral position switch (MT model)

C31

Battery voltage is detected when the shift lever is in any position except for neutral.

“Approx. 0 V” is detected when the shift lever is in neutral position.

Neutral signal (AT model)

C31

Battery voltage is detected when the shift lever is in any position except for “P” or “N”.

“0 V” is detected when the shift lever is in “P” or “N” position.

2. DIESEL ENGINE MODEL

Content

Terminal No.

Measurement condition and I/O signal

(Idling with ignition ON: except for cruise set light)

Main power supply

VB (CONTROL 1)

VB (CONTROL 2)

B2

B3

Battery voltage is detected when the main power is turned ON.

“0 V” is detected when the main power is turned OFF.

Command switch

B17

“0 V” is detected when the command switch is in CANCEL position.

“Approx. 1 V” is detected when the command switch is in SET/COAST position.

“Approx. 3 V” is detected when the command switch is in RESUME/ACCEL position.

“Approx. 4 V” is detected when the command switch is released.

Brake switch 1

(Brake switch)

B19

Battery voltage is detected when the brake pedal is released.

“0 V” is detected when brake pedal is depressed.

Brake switch 2

(Stop light switch)

B18

Battery voltage is detected when brake pedal is depressed.

“0 V” is detected when the brake pedal is released.

Main switch

A29

“0 V” is detected while the main switch is pressed or turned on.

Approx. “5 V” is detected when the main switch is OFF.

Ground

GND (CONTROL 1)

GND (CONTROL 2)

A80

A81

Ignition switch

B10

Battery voltage is detected when the ignition switch is turned ON.

“0 V” is detected when the ignition switch is turned OFF.

Clutch switch (MT model)

A28

“0 V” is detected when clutch pedal is depressed.

Battery voltage is detected when the clutch pedal is released.

Neutral position switch (MT model)

B21

“0 V” is detected when the shift lever is in neutral position.

Battery voltage is detected when the shift lever is in any position except for neutral.