CHECK OUTPUT SIGNAL.

Measure the voltage between the harness connector terminal and chassis ground of double lock unit when moving the key cylinder lock switch to LOCK.

Connector & terminal

(B324) No. 3 (+) — Chassis ground (−):

QUESTION

Is the voltage 10 V or more?

Yes No

Replace the double lock unit.