1) Remove the fuel sub level sensor.
2) Measure the resistance between fuel sub level sensor terminals when the float is in FULL or EMPTY position.
Terminals
No. 1 — No. 2:
Is the resistance 0.5 — 2.5 Ω (FULL) and 42 — 44 Ω (EMPTY)?