| CHECK HARNESS BETWEEN MAIN FAN RELAY AND ECM. |
|
1) Disconnect the connectors from the ECM. 2) Measure the resistance between the main fan relay terminal and ECM connector. Connector & terminal 2.0 L model (B135) No. 19 — (F27) No. 32: 2.5 L model (B136) No. 18 — (F27) No. 32: |