| CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY. |
|
Measure the voltage between ECM and chassis ground. Connector & terminal (B135) No. 34 (+) — Chassis ground: |
| QUESTION | |
|
Is the voltage 10 V or more? | |
| Yes | No |
|
Repair power supply short circuit of the harness between ECM and secondary air combination valve relay. |
Temporary poor contact occurs. Check the poor contact of connector. |