Measure the resistance of harness between tumble generator valve position sensor connector and engine ground.
Connector & terminal
(E50) No. 3 — Engine ground:
Is the resistance 1 MΩ or more?
Repair the ground short circuit of harness between tumble generator valve position sensor and ECM connector.