CHECK INPUT SIGNAL FOR TCM.

1) Move the select lever to any other than “D” range.

2) Measure the voltage between TCM and chassis ground.

Connector & terminal

(B55) No. 10 (+) — Chassis ground (−):

QUESTION

Is the voltage 8 V or more?

Yes No

Replace the TCM.