CHECK KNOCK SENSOR.

Measure the resistance between knock sensor connector terminals.

Terminals

No. 1 — No. 2:

QUESTION

Is the resistance 700 kΩ or more?

Yes No

Repair the harness and connector.

NOTE:

In this case, repair the following item:

Poor contact of knock sensor connector