CHECK FRONT SUB SENSOR (RH).

1) Connect connector (1AA) in the test harness AA to the front sub sensor (RH).

2) Measure resistance between connector (2AA) terminals in the test harness AA.

Connector & terminal

(2AA) No. 1 — (2AA) No. 2:

QUESTION

Is the resistance 750 — 1 KΩ?

Yes No

Replace the front sub sensor (RH).