PERIODIC MAINTENANCE SERVICES > V-belt

INSPECTION

1. Replace the belts, if crack, fraying or wear is found.

2. Check the V-belt tension and adjust it if necessary by changing the generator installing position or idler pulley installing position.

Belt tension

(A)

When replaced: 7.0 — 9.0 mm (0.276 — 0.354 in)
When reusesd: 9.0 — 11.0 mm (0.354 — 0.433 in)

(B)

When replaced: 7.5 — 8.5 mm (0.295 — 0.335 in)
When reusesd: 9.0 — 10.0 mm (0.354 — 0.394 in)

(A)

Front side belt

(B)

Rear side belt

C/P

Crank pulley

GEN

Generator

P/S

Power steering oil pump pulley

A/C

A/C compressor pulley

I/P

Idler pulley