SECURITY AND LOCKS > Door Lock Control System
|
Symptom |
Repair order |
Reference |
|
The door lock control system does not operate. |
1. Check the fuse. |
|
|
2. Check the power supply and ground circuit for the keyless entry control module (model without double lock) or double lock unit (model with double lock). |
||
|
3. Check the door lock switch and the circuit. |
||
|
4. Check the door lock actuator and the circuit. |
||
|
The door lock switch does not operate. |
Check the door lock switch and circuit. |
|
|
A specific door lock actuator does not operate. |
Check the door lock actuator and circuit. |
|
|
The key cylinder lock switch does not operate. (Model with double lock) |
Check the key cylinder lock switch and circuit. |
|
|
The double lock does not operate. (Model with double lock) |
Check the door lock actuator (double lock) and circuit. |
| STEP | CHECK | YES | NO |
|
Is the fuse blown out? |
Replace the fuse with a new part. |
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
| STEP | CHECK | YES | NO |
|
1) Disconnect the keyless entry control module or double lock unit harness connector. 2) Measure the voltage between harness connector terminal and chassis ground. Connector & terminal Model without double lock: (B176) No. 5 (+) — Chassis ground (−): Model with double lock: (B324) No. 7 (+) — Chassis ground (−): |
Is the voltage 10 V or more? |
Check the harness for open circuits or shorts between the keyless entry control module or double lock unit and the fuse. |
|
|
Is the resistance less than 10 Ω? |
The power supply and ground circuit are OK. |
Repair the harness. |
4. CHECK DOOR LOCK SWITCH AND CIRCUIT
5. CHECK DOOR LOCK ACTUATOR AND CIRCUIT
| STEP | CHECK | YES | NO |
|
Measure the voltage between the harness connector terminal and chassis ground of keyless entry control module or double lock unit when moving the door lock switch to LOCK. Connector & terminal Model without double lock: (B176) No. 18 (+) — Chassis ground (−): Model with double lock: (B324) No. 3 (+) — Chassis ground (−): |
Is the voltage 10 V or more? |
Replace the keyless entry control module or double lock unit. |
|
|
Measure the voltage between the harness connector terminal and chassis ground of keyless entry control module or double lock unit when moving the door lock switch to UNLOCK. Connector & terminal Model without double lock: (B176) No. 17 (+) — Chassis ground (−): Model with double lock: (B324) No. 5 (+) — Chassis ground (−): |
Is the voltage 10 V or more? |
Replace the keyless entry control module or double lock unit. |
|
|
Is the door lock actuator OK? |
Check the harness for open circuits or shorts between the keyless entry control module or double lock unit and the door lock actuator. |
Replace the door lock actuator. |
6. CHECK KEY CYLINDER LOCK SWITCH (DOUBLE LOCK) AND CIRCUIT
| STEP | CHECK | YES | NO |
|
Is the resistance less than 10 Ω? |
|||
|
Is the resistance less than 10 Ω? |
The key cylinder lock switch is OK. |
||
|
Is the resistance less than 1 Ω? |
Replace the key cylinder lock switch. |
||
|
Is the resistance less than 1 Ω? |
Check the harness for open circuits or shorts between the double lock unit and the key cylinder lock switch. |
Replace the key cylinder lock switch. |
7. CHECK DOOR LOCK ACTUATOR (DOUBLE LOCK) AND CIRCUIT
| STEP | CHECK | YES | NO |
|
Is the voltage 10 V or more? |
Replace the double lock unit. |
||
|
Is the voltage 10 V or more? |
Replace the double lock unit. |
||
|
Is the door lock actuator OK? |
Check the harness for open circuits or shorts between the double lock unit and the door lock actuator. |
Replace the door lock actuator. |