SECURITY AND LOCKS > Rear Gate Latch Lock Actuator

INSPECTION

1. Disconnect the door lock actuator harness connector.

2. Connect the battery to door lock actuator terminals.

Terminal No.

Actuator operation

No. 4 (+) and No. 2 (−)

Unlock → Lock

No. 2 (+) and No. 4 (−)

Lock → Unlock

If NG, replace the rear gate latch lock actuator.