CONTROL SYSTEMS > General Diagnostic Table
|
Symptoms |
Problem parts |
|
Shift lock does not function. |
• Stop light switch • Shift lock solenoid • AT shift lock control module |
|
Shift lock cannot be released. |
• Stop light switch • Shift lock solenoid • AT shift lock control module • Inhibitor switch |
|
Key interlock does not function. |
• Key warning switch • “P” range switch • Key lock solenoid • AT shift lock control module |
|
Key interlock cannot be released. |
• Key warning switch • “P” range switch • Key lock solenoid • AT shift lock control module |
|
Starter does not run. |
• Inhibitor switch • Select cable • Starter circuit |
|
Back-up light does not illuminate. |
• Inhibitor switch • Select cable • Back-up light circuit |
|
Gear can be shifted from “N” to “R” during driving. |
• Shift lock solenoid • TCM |
|
Does not change to HI or LO. |
• Drive select cable • Transmission |