COOLING(H4SO) > Thermostat

INSPECTION

Replace the thermostat if the valve does not close completely at an ambient temperature or if the following test shows unsatisfactory results.

Inspection method

Immerse the thermostat and a thermometer in water. Raise water temperature gradually, and measure the temperature and valve lift when the valve begins to open and when the valve is fully opened. During the test, agitate the water for even temperature distribution. The measured value should meet the specification.

NOTE:

Leave the thermostat in the boiling water for five minutes or more before measuring valve lift.

Hold the thermostat with a wire or the like to avoid contacting with container bottom.

Starting temperature to open:

Engine side

SOHC MODEL

80 — 84°C (176 — 183°F)

DOHC MODEL

76 — 80°C (169 — 176°F)

ATF warmer side

69 — 73°C (156 — 163°F)

Fully opens:

Engine side

SOHC MODEL

95°C (203°F)

DOHC MODEL

91°C (196°F)

ATF warmer side

84°C (183°F)

Valve lift:

Engine side

9.0 mm (0.354 in) or more

ATF warmer side

8.0 mm (0.31 in) or more

(A)

Thermometer

(B)

Thermostat